TU Darmstadt / ULB / TUbiblio

Dielectric Contrast Between Normal and Tumor Ex-Vivo Human Liver Tissue

Hessinger, Carolin ; Jakoby, Rolf ; Bazrafshan, Babak ; Hübner, Frank ; Schmidt, Sönke ; Schüler, Martin ; Panahi, Bita ; Kaltenbach, Benjamin ; Polkowski, Christoph ; Vogl, Thomas J. (2019)
Dielectric Contrast Between Normal and Tumor Ex-Vivo Human Liver Tissue.
In: IEEE Access, 7
Artikel, Bibliographie

Dies ist die neueste Version dieses Eintrags.

Kurzbeschreibung (Abstract)

Microwave ablation (MWA) is a promising treatment option for patients suffering from liver cancer utilizing electromagnetic wave heating within the targeted tissue at microwave frequencies. Knowledge about the dielectric properties of the targeted tissues is essential for the design of recent MWA systems by including treatment monitoring possibilities. This work focuses on the evaluation of the patient-specific dielectric contrast between healthy and diseased liver parts at discrete frequencies at 2.45 GHz and 5.8 GHz, as well as a broadband data analysis. Measurements yield a frequency-dependent dielectric contrast with local maxima for each patient. Due to large variations between the dielectric properties of the patients, the need for individual thresholds can be derived to distinguish between healthy and malignant tissue.

Typ des Eintrags: Artikel
Erschienen: 2019
Autor(en): Hessinger, Carolin ; Jakoby, Rolf ; Bazrafshan, Babak ; Hübner, Frank ; Schmidt, Sönke ; Schüler, Martin ; Panahi, Bita ; Kaltenbach, Benjamin ; Polkowski, Christoph ; Vogl, Thomas J.
Art des Eintrags: Bibliographie
Titel: Dielectric Contrast Between Normal and Tumor Ex-Vivo Human Liver Tissue
Sprache: Englisch
Publikationsjahr: 2019
Verlag: IEEE
Titel der Zeitschrift, Zeitung oder Schriftenreihe: IEEE Access
Jahrgang/Volume einer Zeitschrift: 7
Zugehörige Links:
Kurzbeschreibung (Abstract):

Microwave ablation (MWA) is a promising treatment option for patients suffering from liver cancer utilizing electromagnetic wave heating within the targeted tissue at microwave frequencies. Knowledge about the dielectric properties of the targeted tissues is essential for the design of recent MWA systems by including treatment monitoring possibilities. This work focuses on the evaluation of the patient-specific dielectric contrast between healthy and diseased liver parts at discrete frequencies at 2.45 GHz and 5.8 GHz, as well as a broadband data analysis. Measurements yield a frequency-dependent dielectric contrast with local maxima for each patient. Due to large variations between the dielectric properties of the patients, the need for individual thresholds can be derived to distinguish between healthy and malignant tissue.

Sachgruppe der Dewey Dezimalklassifikatin (DDC): 600 Technik, Medizin, angewandte Wissenschaften > 600 Technik
Fachbereich(e)/-gebiet(e): 18 Fachbereich Elektrotechnik und Informationstechnik
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Mikrowellentechnik und Photonik (IMP)
Hinterlegungsdatum: 02 Aug 2024 12:34
Letzte Änderung: 02 Aug 2024 12:34
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen