Harenberg, Stefan ; Pahn, Matthias ; Malárics‐Pfaff, Viktória ; Dehn, Frank ; Caggiano, Antonio ; Schicchi, Diego S. ; Yang, Sha ; Koenders, Eddie (2019)
Digital image correlation strain measurement of ultra‐high‐performance concrete‐prisms under static and cyclic bending‐tensile stress.
In: Structural Concrete, 20 (4)
doi: 10.1002/suco.201900033
Artikel, Bibliographie
Dies ist die neueste Version dieses Eintrags.
Kurzbeschreibung (Abstract)
This paper provides experimental results on investigations for the validation of photogrammetric strain measurements of ultra‐high‐performance concrete (UHPC)‐prisms subjected to static and cyclic bending‐tensile stress. For this purpose, 4 static and 5 cyclic test series were performed. Damage progresses during loading are monitored by means of a digital image correlation (DIC) system and a clip gauge. The control of the DIC by trigger lists and the measurement noise as a function of the measurement rate are examined. All static tests were performed force controlled with the same testing speed and the same measuring rate of DIC and clip gauge. All cyclic tests were performed with the same upper and lower stress levels but with different loading rates.
During the static tests, the DIC can be used to make accurate strain measurements before UHPC failure. In the cyclic tests, the measurement noise of the DIC decreases with an increasing measuring rate. The tests performed confirm the control of the DIC by trigger lists for cyclic tests on UHPC‐prisms and show that the measurement noise is negligible in static and cyclic tests.
Typ des Eintrags: | Artikel |
---|---|
Erschienen: | 2019 |
Autor(en): | Harenberg, Stefan ; Pahn, Matthias ; Malárics‐Pfaff, Viktória ; Dehn, Frank ; Caggiano, Antonio ; Schicchi, Diego S. ; Yang, Sha ; Koenders, Eddie |
Art des Eintrags: | Bibliographie |
Titel: | Digital image correlation strain measurement of ultra‐high‐performance concrete‐prisms under static and cyclic bending‐tensile stress |
Sprache: | Englisch |
Publikationsjahr: | 2019 |
Ort: | Malden |
Verlag: | John Wiley & Sons |
Titel der Zeitschrift, Zeitung oder Schriftenreihe: | Structural Concrete |
Jahrgang/Volume einer Zeitschrift: | 20 |
(Heft-)Nummer: | 4 |
DOI: | 10.1002/suco.201900033 |
Zugehörige Links: | |
Kurzbeschreibung (Abstract): | This paper provides experimental results on investigations for the validation of photogrammetric strain measurements of ultra‐high‐performance concrete (UHPC)‐prisms subjected to static and cyclic bending‐tensile stress. For this purpose, 4 static and 5 cyclic test series were performed. Damage progresses during loading are monitored by means of a digital image correlation (DIC) system and a clip gauge. The control of the DIC by trigger lists and the measurement noise as a function of the measurement rate are examined. All static tests were performed force controlled with the same testing speed and the same measuring rate of DIC and clip gauge. All cyclic tests were performed with the same upper and lower stress levels but with different loading rates. During the static tests, the DIC can be used to make accurate strain measurements before UHPC failure. In the cyclic tests, the measurement noise of the DIC decreases with an increasing measuring rate. The tests performed confirm the control of the DIC by trigger lists for cyclic tests on UHPC‐prisms and show that the measurement noise is negligible in static and cyclic tests. |
Freie Schlagworte: | cyclic bending tests, DIC, fatigue, photogrammetry, UHPC |
Zusätzliche Informationen: | Special Issue: Special theme "Fatigue" |
Sachgruppe der Dewey Dezimalklassifikatin (DDC): | 600 Technik, Medizin, angewandte Wissenschaften > 624 Ingenieurbau und Umwelttechnik 600 Technik, Medizin, angewandte Wissenschaften > 690 Hausbau, Bauhandwerk |
Fachbereich(e)/-gebiet(e): | 13 Fachbereich Bau- und Umweltingenieurwissenschaften 13 Fachbereich Bau- und Umweltingenieurwissenschaften > Institut für Werkstoffe im Bauwesen |
Hinterlegungsdatum: | 29 Jan 2024 10:45 |
Letzte Änderung: | 29 Jan 2024 10:45 |
PPN: | |
Export: | |
Suche nach Titel in: | TUfind oder in Google |