TU Darmstadt / ULB / TUbiblio

The Challenge of Stereo PIV Measurements in the Tip Gap of a Transonic Compressor Rotor with Casing Treatment

Voges, Melanie ; Willert, Chris ; Mönig, Reinhard ; Müller, Martin W. ; Schiffer, Heinz-Peter (2010)
The Challenge of Stereo PIV Measurements in the Tip Gap of a Transonic Compressor Rotor with Casing Treatment.
15th International Symposium on Applications of Laser Techniques to Fluid Mechanics.
Konferenzveröffentlichung, Bibliographie

Kurzbeschreibung (Abstract)

This contribution is aimed at summarizing the effort taken to apply stereoscopic PIV (SPIV) measurements in the tip clearance of a transonic compressor rotor equipped with a casing treatment. A light sheet probe was placed downstream of the stator and aligned to pass the light sheet through a stator passage into the blade tip clearance of the rotor. A setup with three cameras has been used in order to record the entire 2C velocity field and the smaller area of 3C field of view at the same time instance for comparison with earlier 2C PIV results. A homogeneous seeding distribution was achieved by means of a smoke generator, working with evaporated and subsequently re-condensed mineral oil. The main emphasis of the SPIV measurement was to establish a data set with high spatial resolution close to the compressor casing, where the aerodynamic effects of a CT are known to be strong. Additionally the SPIV data was intended to be used for comparison with numerical results and related code validation, as detailed laser-based flow field investigations in the vicinity of a casing treatment in a transonic compressor environment are barely reported in the literature. The paper will discuss some major aspects of the utilized PIV data processing and point out a variety of frequently underestimated error sources that influence the overall quality of the recovered data in spite of the fact that the individual PIV recordings seemed to be of very good quality. Thus the authors will not focus on the PIV results and related interpretation of the flow field, but on the optimization and procedures applied during setup of the experiment and data processing respectively.

Typ des Eintrags: Konferenzveröffentlichung
Erschienen: 2010
Autor(en): Voges, Melanie ; Willert, Chris ; Mönig, Reinhard ; Müller, Martin W. ; Schiffer, Heinz-Peter
Art des Eintrags: Bibliographie
Titel: The Challenge of Stereo PIV Measurements in the Tip Gap of a Transonic Compressor Rotor with Casing Treatment
Sprache: Englisch
Publikationsjahr: Juli 2010
Veranstaltungstitel: 15th International Symposium on Applications of Laser Techniques to Fluid Mechanics
URL / URN: http://elib.dlr.de/64651/
Kurzbeschreibung (Abstract):

This contribution is aimed at summarizing the effort taken to apply stereoscopic PIV (SPIV) measurements in the tip clearance of a transonic compressor rotor equipped with a casing treatment. A light sheet probe was placed downstream of the stator and aligned to pass the light sheet through a stator passage into the blade tip clearance of the rotor. A setup with three cameras has been used in order to record the entire 2C velocity field and the smaller area of 3C field of view at the same time instance for comparison with earlier 2C PIV results. A homogeneous seeding distribution was achieved by means of a smoke generator, working with evaporated and subsequently re-condensed mineral oil. The main emphasis of the SPIV measurement was to establish a data set with high spatial resolution close to the compressor casing, where the aerodynamic effects of a CT are known to be strong. Additionally the SPIV data was intended to be used for comparison with numerical results and related code validation, as detailed laser-based flow field investigations in the vicinity of a casing treatment in a transonic compressor environment are barely reported in the literature. The paper will discuss some major aspects of the utilized PIV data processing and point out a variety of frequently underestimated error sources that influence the overall quality of the recovered data in spite of the fact that the individual PIV recordings seemed to be of very good quality. Thus the authors will not focus on the PIV results and related interpretation of the flow field, but on the optimization and procedures applied during setup of the experiment and data processing respectively.

Freie Schlagworte: Stereo PIV, transonic, compressor, casing treatment, processing, measurement error
Fachbereich(e)/-gebiet(e): 16 Fachbereich Maschinenbau
16 Fachbereich Maschinenbau > Fachgebiet für Gasturbinen, Luft- und Raumfahrtantriebe (GLR)
Hinterlegungsdatum: 16 Apr 2018 15:09
Letzte Änderung: 06 Mär 2020 07:20
PPN:
Export:
Suche nach Titel in: TUfind oder in Google
Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen