Hanson, Josef ; Koenig, Dieter (1997)
Fault arcs effects in cable bundles for space applications in vacuum.
In: IEEE Transactions on Dielectrics and Electrical Insulation, 4 (4)
doi: 10.1109/94.625354
Artikel, Bibliographie
Kurzbeschreibung (Abstract)
A multitude of 'arc tracking' tests on cables for space applications has been performed to improve the basic understanding of the phenomena responsible for the fault arc behavior. The damage in a cable bundle develops in a complex system consisting of metallic conductors, insulation materials and arc plasma. Considering the degradation effects, vacuum as one of the applied test parameters, has turned out to be an important test environment. The investigations are based on a new test method, developed to assess arc tracking properties of cables for space applications. Tests were conducted with different insulation materials at cables with different AWG at 125 V dc and nominal currents. The tests were focused on the vacuum environment, using air only for the purpose of comparison. For some cable types, vacuum has turned out to be a worst-case environmental condition with respect to fault arc effects, such as the conductor burn-off, degradation of the insulation of adjacent cables and the extension of the fault arc. This paper presents these worst case experiments in detail.
Typ des Eintrags: | Artikel |
---|---|
Erschienen: | 1997 |
Autor(en): | Hanson, Josef ; Koenig, Dieter |
Art des Eintrags: | Bibliographie |
Titel: | Fault arcs effects in cable bundles for space applications in vacuum |
Sprache: | Englisch |
Publikationsjahr: | 1 August 1997 |
Verlag: | IEEE |
Titel der Zeitschrift, Zeitung oder Schriftenreihe: | IEEE Transactions on Dielectrics and Electrical Insulation |
Jahrgang/Volume einer Zeitschrift: | 4 |
(Heft-)Nummer: | 4 |
DOI: | 10.1109/94.625354 |
Kurzbeschreibung (Abstract): | A multitude of 'arc tracking' tests on cables for space applications has been performed to improve the basic understanding of the phenomena responsible for the fault arc behavior. The damage in a cable bundle develops in a complex system consisting of metallic conductors, insulation materials and arc plasma. Considering the degradation effects, vacuum as one of the applied test parameters, has turned out to be an important test environment. The investigations are based on a new test method, developed to assess arc tracking properties of cables for space applications. Tests were conducted with different insulation materials at cables with different AWG at 125 V dc and nominal currents. The tests were focused on the vacuum environment, using air only for the purpose of comparison. For some cable types, vacuum has turned out to be a worst-case environmental condition with respect to fault arc effects, such as the conductor burn-off, degradation of the insulation of adjacent cables and the extension of the fault arc. This paper presents these worst case experiments in detail. |
Fachbereich(e)/-gebiet(e): | 18 Fachbereich Elektrotechnik und Informationstechnik 18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme > Hochspannungstechnik 18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme |
Hinterlegungsdatum: | 19 Nov 2008 16:05 |
Letzte Änderung: | 10 Mai 2023 10:19 |
PPN: | |
Export: | |
Suche nach Titel in: | TUfind oder in Google |
Frage zum Eintrag |
Optionen (nur für Redakteure)
Redaktionelle Details anzeigen |