TU Darmstadt / ULB / TUbiblio

Magnetic Resonance Velocimetry for Unsteady Flows

Freudenhammer, Daniel Kim (2016)
Magnetic Resonance Velocimetry for Unsteady Flows.
Technische Universität Darmstadt
Dissertation, Erstveröffentlichung

Kurzbeschreibung (Abstract)

Magnetic Resonance Imaging (MRI) is an established tool for clinical diagnostics. The measurement technique can be used to measure blood flow, then denoted Flow MRI or Magnetic Resonance Velocimetry (MRV). MRV has in recent years also found increasing consideration in the field of fluid mechanics, where it is esteemed for its unique capabilities of measuring fully volumetric velocity fields without the need for optical access and without manipulating the flow under investigation. MRV is typically used for the acquisition of mean velocity fields in water flows. This study deals with the possibility of acquiring velocity fields in steady, unsteady and turbulent flows. Besides the application of the different MR techniques in selected test cases, validation of the acquired measurement data is a main topic of this thesis.

Mean flow measurements are acquired within steady flow model of a modern IC engine. The acquired flow data is validated by means of PIV data and excellent agreement is found. The three-dimensional nature of the acquired flow field enables new insights into the volumetric flow field distribution. Unsteady periodic flows are analyzed by means of the 4D MRV measurement sequence,which acquires phase-averaged, volumetric velocity fields. The acquired flow data is extensively validated by means of Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV) data and valid flow regions are identified. A comprehensive understanding of the unsteady, periodic flow field evolution during intake stroke is enabled for the measurements inside the modified engine flow model. MR turbulence measurements, for the acquisition of normal and shear stresses within the flow field, are conducted within a Backward Facing Step (BFS) geometry, which provides optical access for comparative LDV validation measurements through a perspex insert. MR turbulence measurements inside the engine flow model demonstrate the potential of the measurements regarding their application in complex geometries. Validation of the measurements shows a reasonable agreement for normal stresses, while the determination of shear stresses remains still rather inaccurate.

Typ des Eintrags: Dissertation
Erschienen: 2016
Autor(en): Freudenhammer, Daniel Kim
Art des Eintrags: Erstveröffentlichung
Titel: Magnetic Resonance Velocimetry for Unsteady Flows
Sprache: Englisch
Referenten: Tropea, Prof. Dr. Cameron ; Hennig, Prof. Dr. Jürgen
Publikationsjahr: 2 August 2016
Ort: Darmstadt
Datum der mündlichen Prüfung: 16 November 2016
URL / URN: http://tuprints.ulb.tu-darmstadt.de/5847
Kurzbeschreibung (Abstract):

Magnetic Resonance Imaging (MRI) is an established tool for clinical diagnostics. The measurement technique can be used to measure blood flow, then denoted Flow MRI or Magnetic Resonance Velocimetry (MRV). MRV has in recent years also found increasing consideration in the field of fluid mechanics, where it is esteemed for its unique capabilities of measuring fully volumetric velocity fields without the need for optical access and without manipulating the flow under investigation. MRV is typically used for the acquisition of mean velocity fields in water flows. This study deals with the possibility of acquiring velocity fields in steady, unsteady and turbulent flows. Besides the application of the different MR techniques in selected test cases, validation of the acquired measurement data is a main topic of this thesis.

Mean flow measurements are acquired within steady flow model of a modern IC engine. The acquired flow data is validated by means of PIV data and excellent agreement is found. The three-dimensional nature of the acquired flow field enables new insights into the volumetric flow field distribution. Unsteady periodic flows are analyzed by means of the 4D MRV measurement sequence,which acquires phase-averaged, volumetric velocity fields. The acquired flow data is extensively validated by means of Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV) data and valid flow regions are identified. A comprehensive understanding of the unsteady, periodic flow field evolution during intake stroke is enabled for the measurements inside the modified engine flow model. MR turbulence measurements, for the acquisition of normal and shear stresses within the flow field, are conducted within a Backward Facing Step (BFS) geometry, which provides optical access for comparative LDV validation measurements through a perspex insert. MR turbulence measurements inside the engine flow model demonstrate the potential of the measurements regarding their application in complex geometries. Validation of the measurements shows a reasonable agreement for normal stresses, while the determination of shear stresses remains still rather inaccurate.

Alternatives oder übersetztes Abstract:
Alternatives AbstractSprache

Magnetresonanztomographie (MRT, englisch MRI) ist eine bewährte Messtechnik im Bereich der klinischen Diagnose. MRI ermöglicht das Vermessen von Geschwindigkeitsfeldern, dann Flow MRI bzw. Magnetic Resonance Velocimetry (MRV) genannt. MRV findet zunehmend Anwendung im Bereich der Strömungsmechanik, wo es aufgrund seiner Besonderheit geschätzt wird: Die Ermittlung dreidimensionaler Geschwindigkeitsfelder ohne Strömungsbeeinflussung und ohne Notwendigkeit eines optischen Zugangs.

Gegenstand dieser Arbeit ist die Anwendung von MRV in stationären sowie in instationären periodischen Strömungen. Außerdem soll MRV zur Quantifizierung turbulenter Strömungen dienen. Zu diesem Zweck werden unterschiedliche MRV Sequenzen verwendet und in ausgewählten Strömungsgeometrien appliziert. Die Validierung dieser Sequenzen steht dabei im Vordergrund und wird durch Validationsmessungen mittels etablierter Messtechnik realisiert.

Stationäre Messungen werden in einem Modell eines Viertakt Ottomotors durchgeführt. Die Validierung mittels Particle Image Velocimetry (PIV) Messungen ergibt eine sehr gute Übereinstimmung beider Messtechniken. Die ermittelten dreidimensionalen Strömungsfelder bieten neue Möglichkeiten der Strömungsanalyse. Für ein tiefgreifendes Verständnis instationärer periodischer Strömungendes, können Diese mit Hilfe von 4D MRV Messungen aufgenommen werden. Die Messdaten werden mit optischer Messtechnik (PIV und LDV) validiert. Bereiche guter Übereinstimmung werden identifiziert, auftretende Differenzen erläutert. Die Ermittlung von Komponenten des Reynoldsschen Spannungstensors in turbulenten Strömungen wird durch MR Turbulenzmessungen ermöglicht. Diese Messungen werden in zwei unterschiedlichen Strömungsmodellen präsentiert. Die Validierung dieser Messungen ergibt eine recht gute Übereinstimmung in der Bestimmung der Normalspannungskompo- nenten, während die Bestimmung von Schubspannungen noch fehlerbehaftet ist. Potentielle Fehlerquellen werden diskutiert.

Deutsch
Freie Schlagworte: Magnetic Resonance Velocimetry, MRV, MRI, IC-engine, IC engine, intake flow, unsteady flows, BFS, Backward facing step,
URN: urn:nbn:de:tuda-tuprints-58472
Sachgruppe der Dewey Dezimalklassifikatin (DDC): 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften und Maschinenbau
Fachbereich(e)/-gebiet(e): 16 Fachbereich Maschinenbau > Fachgebiet Strömungslehre und Aerodynamik (SLA)
16 Fachbereich Maschinenbau
Hinterlegungsdatum: 22 Jan 2017 20:55
Letzte Änderung: 22 Jan 2017 20:55
PPN:
Referenten: Tropea, Prof. Dr. Cameron ; Hennig, Prof. Dr. Jürgen
Datum der mündlichen Prüfung / Verteidigung / mdl. Prüfung: 16 November 2016