Heinrich, C. ; Hinrichsen, Volker (2001)
Diagnostics and Monitoring of Metal-Oxide Surge Arresters in High-Voltage Networks - Comparison of Existing and Newly Developed Procedures.
In: IEEE Transactions on Power Delivery, 16 (1)
Artikel, Bibliographie
Kurzbeschreibung (Abstract)
Various diagnostic methods-either on-line or off-line-for monitoring of metal-oxide surge arresters in power systems are known. In most cases they are based on the measurement of the leakage current. This paper describes the most important ones in detail, such as measuring of the V-I-characteristics or analysis of the third harmonic content of the leakage current. Their advantages and weak points, respectively, are discussed, based on the most recent investigation results on the change of the V-I-characteristics due to electrical and nonelectrical stresses. It turns out that almost none of these commonly applied methods really work satisfactorily under either technical or economical aspects. As an alternative the temperature of the MO-insert is proposed to be used for diagnostics purposes. This is made possible by newly developed passive temperature sensors, which can be remotely accessed without any hardware connection to the environment. It is shown how the temperature can be used for monitoring of all kinds of degradation, energy absorption, thermal stability or even pollution performance.
Typ des Eintrags: | Artikel |
---|---|
Erschienen: | 2001 |
Autor(en): | Heinrich, C. ; Hinrichsen, Volker |
Art des Eintrags: | Bibliographie |
Titel: | Diagnostics and Monitoring of Metal-Oxide Surge Arresters in High-Voltage Networks - Comparison of Existing and Newly Developed Procedures |
Sprache: | Englisch |
Publikationsjahr: | Januar 2001 |
Verlag: | IEEE |
Titel der Zeitschrift, Zeitung oder Schriftenreihe: | IEEE Transactions on Power Delivery |
Jahrgang/Volume einer Zeitschrift: | 16 |
(Heft-)Nummer: | 1 |
Kurzbeschreibung (Abstract): | Various diagnostic methods-either on-line or off-line-for monitoring of metal-oxide surge arresters in power systems are known. In most cases they are based on the measurement of the leakage current. This paper describes the most important ones in detail, such as measuring of the V-I-characteristics or analysis of the third harmonic content of the leakage current. Their advantages and weak points, respectively, are discussed, based on the most recent investigation results on the change of the V-I-characteristics due to electrical and nonelectrical stresses. It turns out that almost none of these commonly applied methods really work satisfactorily under either technical or economical aspects. As an alternative the temperature of the MO-insert is proposed to be used for diagnostics purposes. This is made possible by newly developed passive temperature sensors, which can be remotely accessed without any hardware connection to the environment. It is shown how the temperature can be used for monitoring of all kinds of degradation, energy absorption, thermal stability or even pollution performance. |
Fachbereich(e)/-gebiet(e): | 18 Fachbereich Elektrotechnik und Informationstechnik 18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme > Hochspannungstechnik 18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme |
Hinterlegungsdatum: | 27 Mai 2015 07:19 |
Letzte Änderung: | 31 Okt 2018 14:40 |
PPN: | |
Export: | |
Suche nach Titel in: | TUfind oder in Google |
Frage zum Eintrag |
Optionen (nur für Redakteure)
Redaktionelle Details anzeigen |