High-resolution diffusion tensor imaging and tractography of the human optic chiasm at 9.4 T.

Roebroeck, Alard ; Galuske, Ralf A. W. ; Formisano, Elia ; Chiry, Oriana ; Bratzke, Hansjürgen ; Ronen, Itamar ; Kim, Dae-shik ; Goebel, Rainer (2008)
High-resolution diffusion tensor imaging and tractography of the human optic chiasm at 9.4 T.
In: NeuroImage, 39 (1)
Artikel, Bibliographie

Kurzbeschreibung (Abstract)

The optic chiasm with its complex fiber micro-structure is a challenge for diffusion tensor models and tractography methods. Likewise, it is an ideal candidate for evaluation of diffusion tensor imaging tractography approaches in resolving inter-regional connectivity because the macroscopic connectivity of the optic chiasm is well known. Here, high-resolution (156 microm in-plane) diffusion tensor imaging of the human optic chiasm was performed ex vivo at ultra-high field (9.4 T). Estimated diffusion tensors at this high resolution were able to capture complex fiber configurations such as sharp curves, and convergence and divergence of tracts, but were unable to resolve directions at sites of crossing fibers. Despite the complex microstructure of the fiber paths through the optic chiasm, all known connections could be tracked by a line propagation algorithm. However, fibers crossing from the optic nerve to the contralateral tract were heavily underrepresented, whereas ipsilateral nerve-to-tract connections, as well as tract-to-tract connections, were overrepresented, and erroneous nerve-to-nerve connections were tracked. The effects of spatial resolution and the varying degrees of partial volume averaging of complex fiber architecture on the performance of these methods could be investigated. Errors made by the tractography algorithm at high resolution were shown to increase at lower resolutions closer to those used in vivo. This study shows that increases in resolution, made possible by higher field strengths, improve the accuracy of DTI-based tractography. More generally, post-mortem investigation of fixed tissue samples with diffusion imaging at high field strengths is important in the evaluation of MR-based diffusion models and tractography algorithms.

Typ des Eintrags: Artikel
Erschienen: 2008
Autor(en): Roebroeck, Alard ; Galuske, Ralf A. W. ; Formisano, Elia ; Chiry, Oriana ; Bratzke, Hansjürgen ; Ronen, Itamar ; Kim, Dae-shik ; Goebel, Rainer
Art des Eintrags: Bibliographie
Titel: High-resolution diffusion tensor imaging and tractography of the human optic chiasm at 9.4 T.
Sprache: Englisch
Publikationsjahr: 2008
Titel der Zeitschrift, Zeitung oder Schriftenreihe: NeuroImage
Jahrgang/Volume einer Zeitschrift: 39
(Heft-)Nummer: 1
Kurzbeschreibung (Abstract):

The optic chiasm with its complex fiber micro-structure is a challenge for diffusion tensor models and tractography methods. Likewise, it is an ideal candidate for evaluation of diffusion tensor imaging tractography approaches in resolving inter-regional connectivity because the macroscopic connectivity of the optic chiasm is well known. Here, high-resolution (156 microm in-plane) diffusion tensor imaging of the human optic chiasm was performed ex vivo at ultra-high field (9.4 T). Estimated diffusion tensors at this high resolution were able to capture complex fiber configurations such as sharp curves, and convergence and divergence of tracts, but were unable to resolve directions at sites of crossing fibers. Despite the complex microstructure of the fiber paths through the optic chiasm, all known connections could be tracked by a line propagation algorithm. However, fibers crossing from the optic nerve to the contralateral tract were heavily underrepresented, whereas ipsilateral nerve-to-tract connections, as well as tract-to-tract connections, were overrepresented, and erroneous nerve-to-nerve connections were tracked. The effects of spatial resolution and the varying degrees of partial volume averaging of complex fiber architecture on the performance of these methods could be investigated. Errors made by the tractography algorithm at high resolution were shown to increase at lower resolutions closer to those used in vivo. This study shows that increases in resolution, made possible by higher field strengths, improve the accuracy of DTI-based tractography. More generally, post-mortem investigation of fixed tissue samples with diffusion imaging at high field strengths is important in the evaluation of MR-based diffusion models and tractography algorithms.

Fachbereich(e)/-gebiet(e): 10 Fachbereich Biologie > Systemische Neurophysiologie
?? fb10_zoologie ??
10 Fachbereich Biologie
Hinterlegungsdatum: 21 Feb 2012 14:11
Letzte Änderung: 05 Mär 2013 09:58
PPN:
Export:
Suche nach Titel in: TUfind oder in Google
Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen