Gating for scanned ion beam therapy

Steidl, Peter (2011)
Gating for scanned ion beam therapy.
Buch, Zweitveröffentlichung

WarnungEs ist eine neuere Version dieses Eintrags verfügbar.

Kurzbeschreibung (Abstract)

In treatment of motion affected tumours by means of a scanned particle beam severe under and over dosage can occur due to the interplay effect. By using gated beam delivery effective target motion is reduced, but even for the residual motion the interplay effect can lead to unsatisfactory dose distributions. Furthermore, an appropriate motion monitoring system is essential since beam delivery has to be synchronized to target motion. In this work three aspects were investigated to move gating closer towards clinical operation at Heidelberg Ion-Beam Therapy Center (HIT): Firstly, influences of beam parameters on dosimetric effects of residual motion were investigated in experiments and simulations. Increased focus sizes and reduced iso-energy distances turned out to be an effective method to gain dose homogeneity whereas reduction of lateral beam position spacing did not show such an effect. Secondly, to enable systematic studies of mitigation techniques and effects of miscorrelation between motion monitoring system and tumour motion a phantom with 6D target and independent thorax motion was constructed and validated successfully in experiments. Thirdly, two motion monitoring systems by VisionRT Ltd. and Anzai Medical Co.,Ltd., respectively, were compared in terms of gating delays and correlation to tumour motion extracted from MV-fluoroscopy. While the VisionRT system showed larger delays than the Anzai system under laboratory conditions, no significant difference between the systems with respect to tumour-correlation was found in a clinical study. Results of this work will be incorporated into patient treatments using gating that will start at HIT within the next few months. Furthermore, a phantom simulating thorax and target motion with a variety of applications such as 4D imaging is now available and already in use by several groups.

Typ des Eintrags: Buch
Erschienen: 2011
Autor(en): Steidl, Peter
Art des Eintrags: Zweitveröffentlichung
Titel: Gating for scanned ion beam therapy
Sprache: Englisch
Referenten: Durante, Prof. Marco ; Kraft, Prof. Gerhard
Publikationsjahr: 21 Dezember 2011
Ort: Darmstadt
Verlag: GSI Helmholtzzentrum für Schwerionenforschung
Band einer Reihe: 11/13
Datum der mündlichen Prüfung: 12 Dezember 2011
URL / URN: urn:nbn:de:tuda-tuprints-28496
Kurzbeschreibung (Abstract):

In treatment of motion affected tumours by means of a scanned particle beam severe under and over dosage can occur due to the interplay effect. By using gated beam delivery effective target motion is reduced, but even for the residual motion the interplay effect can lead to unsatisfactory dose distributions. Furthermore, an appropriate motion monitoring system is essential since beam delivery has to be synchronized to target motion. In this work three aspects were investigated to move gating closer towards clinical operation at Heidelberg Ion-Beam Therapy Center (HIT): Firstly, influences of beam parameters on dosimetric effects of residual motion were investigated in experiments and simulations. Increased focus sizes and reduced iso-energy distances turned out to be an effective method to gain dose homogeneity whereas reduction of lateral beam position spacing did not show such an effect. Secondly, to enable systematic studies of mitigation techniques and effects of miscorrelation between motion monitoring system and tumour motion a phantom with 6D target and independent thorax motion was constructed and validated successfully in experiments. Thirdly, two motion monitoring systems by VisionRT Ltd. and Anzai Medical Co.,Ltd., respectively, were compared in terms of gating delays and correlation to tumour motion extracted from MV-fluoroscopy. While the VisionRT system showed larger delays than the Anzai system under laboratory conditions, no significant difference between the systems with respect to tumour-correlation was found in a clinical study. Results of this work will be incorporated into patient treatments using gating that will start at HIT within the next few months. Furthermore, a phantom simulating thorax and target motion with a variety of applications such as 4D imaging is now available and already in use by several groups.

Alternatives oder übersetztes Abstract:
Alternatives AbstractSprache

Die Bestrahlung bewegter Tumore mit einem gescannten Teilchenstrahl bedarf besonderer Techniken, um durch die Bewegung verursachte Unter- und Überdosierungen zu vermeiden. Eine solche Technik ist die atemsynchronisiert unterbrochene Bestrahlung (Gating), mit der man eine Reduzierung der effektiven Tumorbewegung erreicht. Da diese allerdings nicht völlig kompensiert wird, kann es auch hier auf Grund des Interplay-Effekts zu unakzeptablen Dosisverteilungen kommen. Zudem ist ein Bewegungserfassungssystem erforderlich, mit dem Dosisapplikation und Zielbewegung synchronisiert werden. In Experimenten und Simulationen wurde die Abhängigkeit des Interplay-Effekts für verschiedene Restbewegungsamplituden von Bestrahlungsparametern dosimetrisch untersucht. Es konnte nachgewiesen werden, dass insbesondere ein vergrößerter Strahlfokus zu einer signifikanten Reduzierung der Dosisinhomogenitäten führen kann. Bei der Verwendung von Surrogaten zur Erfassung der Tumorbewegung kann es zu Ungenauigkeiten durch Fehlkorrelationen kommen. Um diese in zukünftigen Studien dosimetrisch quantifizieren zu können, wurde ein Phantom, das Thoraxatmung und unabhängige 6D-Tumorbewegung simulieren kann, entwickelt und erfolgreich experimentell validiert. Schließlich wurden zwei Bewegungserfassungssysteme von VisionRT Ltd. bzw. Anzai Medical Co.,Ltd. evaluiert. Hauptaugenmerk lag dabei auf der Quantifizierung von Gating- Verzögerungen und auf der Korrelation zu Tumorbewegungen. Die Ergebnisse dieser Arbeit werden für die Gating-Bestrahlungen von Patienten am HIT, die in den nächsten Monaten beginnen sollen, verwendet werden. Zudem steht nun ein Bestrahlungsphantom zur Verfügung, das viele Einsatzmöglichkeiten bietet und bereits jetzt von mehreren Forschungsgruppen genutzt wird.

Deutsch
Zusätzliche Informationen:

Darmstadt, Techn. Univ., Diss., 2011

Sachgruppe der Dewey Dezimalklassifikatin (DDC): 500 Naturwissenschaften und Mathematik > 530 Physik
Fachbereich(e)/-gebiet(e): 05 Fachbereich Physik
05 Fachbereich Physik > Institut für Festkörperphysik (2021 umbenannt in Institut für Physik Kondensierter Materie (IPKM))
05 Fachbereich Physik > Institut für Festkörperphysik (2021 umbenannt in Institut für Physik Kondensierter Materie (IPKM)) > Biophysik
Hinterlegungsdatum: 16 Jan 2012 10:38
Letzte Änderung: 26 Jun 2024 06:10
PPN:
Referenten: Durante, Prof. Marco ; Kraft, Prof. Gerhard
Datum der mündlichen Prüfung / Verteidigung / mdl. Prüfung: 12 Dezember 2011
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen