Gail, Gabriele ; Tröster, E. ; Henschel, M. ; Hartkopf, Th. ; Höffling, M. (2006)
Static and dynamic measurements of a permanent magnet induction generator : test results of a new wind generator concept.
International Conference on Electrical Machines (ICEM'04). Cracow, Poland (05.09.2004-08.09.2004)
doi: 10.1007/978-1-4020-4535-6_31
Konferenzveröffentlichung, Bibliographie
Kurzbeschreibung (Abstract)
The Permanent Magnet Induction Machine, a new wind generator concept, is considered to be a highly efficient, low maintenance solution for offshore wind turbines. Static and dynamic measurements have been performed with a test machine. Due to the inherent soft behavior of that machine type compared to normal synchronous machines, no dynamic excitation is found during operation that might endanger the stability of the system. Results of static measurements show high efficiency and little reactive power consumption.
Typ des Eintrags: | Konferenzveröffentlichung |
---|---|
Erschienen: | 2006 |
Autor(en): | Gail, Gabriele ; Tröster, E. ; Henschel, M. ; Hartkopf, Th. ; Höffling, M. |
Art des Eintrags: | Bibliographie |
Titel: | Static and dynamic measurements of a permanent magnet induction generator : test results of a new wind generator concept |
Sprache: | Englisch |
Publikationsjahr: | 2006 |
Ort: | Dordrecht |
Verlag: | Springer |
Buchtitel: | Recent Developments of Electrical Drives : Best papers from the International Conference on Electrical Machines ICEM'04 |
Veranstaltungstitel: | International Conference on Electrical Machines (ICEM'04) |
Veranstaltungsort: | Cracow, Poland |
Veranstaltungsdatum: | 05.09.2004-08.09.2004 |
DOI: | 10.1007/978-1-4020-4535-6_31 |
Zugehörige Links: | |
Kurzbeschreibung (Abstract): | The Permanent Magnet Induction Machine, a new wind generator concept, is considered to be a highly efficient, low maintenance solution for offshore wind turbines. Static and dynamic measurements have been performed with a test machine. Due to the inherent soft behavior of that machine type compared to normal synchronous machines, no dynamic excitation is found during operation that might endanger the stability of the system. Results of static measurements show high efficiency and little reactive power consumption. |
Fachbereich(e)/-gebiet(e): | 18 Fachbereich Elektrotechnik und Informationstechnik |
Hinterlegungsdatum: | 20 Nov 2008 08:26 |
Letzte Änderung: | 21 Nov 2024 11:21 |
PPN: | |
Export: | |
Suche nach Titel in: | TUfind oder in Google |
Frage zum Eintrag |
Optionen (nur für Redakteure)
Redaktionelle Details anzeigen |