Boehm, Stefan ; Schumacher, Knut ; Meissner, Peter (2006)
Q-factor based performance analysis of PMD measurement methods.
Northern Optics 2006: the joint conference of the Optical Societies of Denmark, Finland, Lithuania, and Sweden, and the Physical Soieties of Estonia, Latvia, and Norway. Bergen, Norway (14.06.2006-16.06.2006)
doi: 10.1109/NO.2006.348367
Konferenzveröffentlichung, Bibliographie
Kurzbeschreibung (Abstract)
In this contribution the performance of two methods for monitoring the polarization mode dispersion (PMD) of a transmission line without data traffic interruption are analyzed and compared using numerical simulations. The monitored PMD is used as control signal to set a PMD compensator and the Q- factor after the compensator is taken to assess the performance of the monitoring method. It is shown for the first time that an accurately measured PMD does not necessarily result in an optimal setting of a feed-forward compensator and vice versa.
Typ des Eintrags: | Konferenzveröffentlichung |
---|---|
Erschienen: | 2006 |
Autor(en): | Boehm, Stefan ; Schumacher, Knut ; Meissner, Peter |
Art des Eintrags: | Bibliographie |
Titel: | Q-factor based performance analysis of PMD measurement methods |
Sprache: | Englisch |
Publikationsjahr: | 2006 |
Ort: | Piscataway |
Verlag: | IEEE Operations Center |
Buchtitel: | Northern Optics 2006 conference proceedings : the joint conference of the Optical Societies of Denmark, Finland, Lithuania, and Sweden, and the Physical Soieties of Estonia, Latvia, and Norway ; 14 - 16 June, 2006, Bergen, Norway / organized on behalf of. |
Veranstaltungstitel: | Northern Optics 2006: the joint conference of the Optical Societies of Denmark, Finland, Lithuania, and Sweden, and the Physical Soieties of Estonia, Latvia, and Norway |
Veranstaltungsort: | Bergen, Norway |
Veranstaltungsdatum: | 14.06.2006-16.06.2006 |
DOI: | 10.1109/NO.2006.348367 |
Kurzbeschreibung (Abstract): | In this contribution the performance of two methods for monitoring the polarization mode dispersion (PMD) of a transmission line without data traffic interruption are analyzed and compared using numerical simulations. The monitored PMD is used as control signal to set a PMD compensator and the Q- factor after the compensator is taken to assess the performance of the monitoring method. It is shown for the first time that an accurately measured PMD does not necessarily result in an optimal setting of a feed-forward compensator and vice versa. |
Fachbereich(e)/-gebiet(e): | 18 Fachbereich Elektrotechnik und Informationstechnik |
Hinterlegungsdatum: | 20 Nov 2008 08:26 |
Letzte Änderung: | 21 Nov 2024 12:12 |
PPN: | |
Export: | |
Suche nach Titel in: | TUfind oder in Google |
Frage zum Eintrag |
Optionen (nur für Redakteure)
Redaktionelle Details anzeigen |