TU Darmstadt / ULB / TUbiblio

Evaluation of Different Measurement Methods to Determine Stray Load Losses in Induction Machines

Aoulkadi, M'hamed ; Binder, Andreas (2006)
Evaluation of Different Measurement Methods to Determine Stray Load Losses in Induction Machines.
International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM 2006). Taormina, Italy (23.05.2006-26.05.2006)
doi: 10.1109/SPEEDAM.2006.1649904
Konferenzveröffentlichung, Bibliographie

Kurzbeschreibung (Abstract)

Five different test methods for the determination of stray load losses of line-operated induction machines are compared and the results obtained are discussed. The five experimental measurement procedures are: input-output tests acc. to IEC 61972 (A) and IEEE 112-method B (B), reverse rotation test (RRT) (C) acc. to the standard IEEE 112, eh-star-circuit (D) and equivalent no-load method (E). The advantages and disadvantages of these measurement methods are shown. Nineteen cage induction motors (2-, 4- and 6-pole) with current design of six European manufacturers with rated power 1.1 kW, 5.5 kW and 11 kW are investigated. RRT method yields higher stray load losses, whereas results of IEC 61972, IEEE 112-method B and eh-star-circuit results correlate quite well. The results of equivalent no-load method are either greater or less than values of IEEE 112-method B, and only in some cases are fitting quite well. The eh-star method seems to be a good, lower cost alternative for determination of stray load losses of induction machines.

Typ des Eintrags: Konferenzveröffentlichung
Erschienen: 2006
Autor(en): Aoulkadi, M'hamed ; Binder, Andreas
Art des Eintrags: Bibliographie
Titel: Evaluation of Different Measurement Methods to Determine Stray Load Losses in Induction Machines
Sprache: Englisch
Publikationsjahr: 2006
Ort: Piscataway
Verlag: IEEE
Buchtitel: International Symposium on Power Electronics, Electrical Drives, Automation and Motion, 2006. SPEEDAM 2006
Veranstaltungstitel: International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM 2006)
Veranstaltungsort: Taormina, Italy
Veranstaltungsdatum: 23.05.2006-26.05.2006
DOI: 10.1109/SPEEDAM.2006.1649904
Kurzbeschreibung (Abstract):

Five different test methods for the determination of stray load losses of line-operated induction machines are compared and the results obtained are discussed. The five experimental measurement procedures are: input-output tests acc. to IEC 61972 (A) and IEEE 112-method B (B), reverse rotation test (RRT) (C) acc. to the standard IEEE 112, eh-star-circuit (D) and equivalent no-load method (E). The advantages and disadvantages of these measurement methods are shown. Nineteen cage induction motors (2-, 4- and 6-pole) with current design of six European manufacturers with rated power 1.1 kW, 5.5 kW and 11 kW are investigated. RRT method yields higher stray load losses, whereas results of IEC 61972, IEEE 112-method B and eh-star-circuit results correlate quite well. The results of equivalent no-load method are either greater or less than values of IEEE 112-method B, and only in some cases are fitting quite well. The eh-star method seems to be a good, lower cost alternative for determination of stray load losses of induction machines.

Fachbereich(e)/-gebiet(e): 18 Fachbereich Elektrotechnik und Informationstechnik
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiewandlung > Elektrische Energiewandlung
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiewandlung
Hinterlegungsdatum: 20 Nov 2008 08:25
Letzte Änderung: 26 Nov 2024 12:22
PPN:
Export:
Suche nach Titel in: TUfind oder in Google
Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen