Kurzbeschreibung (Abstract)

We propose a terrestrial detector for gravitational waves with frequencies between 0.3 and 5 Hz based on atom interferometry. As key elements, we discuss two symmetric matter-wave interferometers, the first one with a single loop and the second one featuring a folded triple-loop geometry. The latter eliminates the need for atomic ensembles at femtokelvin energies imposed by the Sagnac effect in other atom interferometric detectors. The folded triple-loop geometry also combines several advantages of current vertical and horizontal matter wave antennas and enhances the scalability in order to achieve a peak strain sensitivity of 2×10^(-21)/√(Hz).

Typ des Eintrags: Artikel
Erschienen: 2024
Autor(en): Schubert, C. ; Schlippert, D. ; Gersemann, M. ; Abend, S. ; Giese, E. ; Roura, A. ; Schleich, W. P. ; Ertmer, W. ; Rasel, E. M.
Art des Eintrags: Bibliographie
Titel: A scalable, symmetric atom interferometer for infrasound gravitational wave detection
Sprache: Englisch
Publikationsjahr: Dezember 2024
Verlag: AIP Publishing
Titel der Zeitschrift, Zeitung oder Schriftenreihe: AVS Quantum Science
Jahrgang/Volume einer Zeitschrift: 6
(Heft-)Nummer: 4
Kollation: 11 Seiten
DOI: 10.1116/5.0228398
Zugehörige Links:
Kurzbeschreibung (Abstract):

We propose a terrestrial detector for gravitational waves with frequencies between 0.3 and 5 Hz based on atom interferometry. As key elements, we discuss two symmetric matter-wave interferometers, the first one with a single loop and the second one featuring a folded triple-loop geometry. The latter eliminates the need for atomic ensembles at femtokelvin energies imposed by the Sagnac effect in other atom interferometric detectors. The folded triple-loop geometry also combines several advantages of current vertical and horizontal matter wave antennas and enhances the scalability in order to achieve a peak strain sensitivity of 2×10^(-21)/√(Hz).

ID-Nummer: Artikel-ID: 044404
Zusätzliche Informationen:

Erstveröffentlichung

Fachbereich(e)/-gebiet(e): 05 Fachbereich Physik
05 Fachbereich Physik > Institut für Angewandte Physik
05 Fachbereich Physik > Institut für Angewandte Physik > Theoretische Quantenoptik
05 Fachbereich Physik > Institut für Angewandte Physik > Theoretische Quantenphysik
Hinterlegungsdatum: 28 Nov 2024 09:29
Letzte Änderung: 28 Nov 2024 09:32
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen