Kurzbeschreibung (Abstract)

Spray cooling is a very efficient method for thermal management of high-performance electronics. The performance of spray cooling is determined by the fluid dynamics and the heat transport when a single drop or multiple drops hit the superheated wall. To understand this process, we numerically study the generic situation of simultaneous impingement of periodic drop arrays onto a superheated wall. We study three different cases in which the distance between the drops varies. The refrigerant used is perfluorohexane (FC-72) in a pure vapor atmosphere under saturation conditions. Drops impinge at moderate Reynolds and Weber numbers, where no splashing occurs during single drop impingement. The wall temperature is above the saturation temperature of the fluid but below the onset of nucleate boiling. Simulations are performed using the OpenFOAM software library, taking into account a dynamic contact angle, evaporation and conjugate heat transfer. We show that the coalescence of more than two drops results in the formation of a liquid jet. A small distance between the drops results in the formation of a thin liquid film while a large distance results in small drops sitting on the wall. In the latter case, the largest amount of heat is transferred, but the occurrence of dry spots is undesirable for cooling applications. The results contribute to a better understanding of spray cooling and provide a perspective for efficient spray cooling.

Typ des Eintrags: Konferenzveröffentlichung
Erschienen: 2024
Autor(en): Sontheimer, Henrik ; Kind, Johannes ; Stephan, Peter ; Gambaryan-Roisman, Tatiana
Art des Eintrags: Zweitveröffentlichung
Titel: Numerical simulation of drop array impingement onto a superheated wall
Sprache: Englisch
Publikationsjahr: 5 Juli 2024
Ort: Darmstadt
Publikationsdatum der Erstveröffentlichung: 2024
Ort der Erstveröffentlichung: Shanghai
Kollation: 10 ungezählte Seiten
Veranstaltungstitel: ICLASS 2024, 16th Triennial International Conference on Liquid Atomization and Spray Systems
Veranstaltungsort: Shanghai, China
Veranstaltungsdatum: June 23-27, 2024
DOI: 10.26083/tuprints-00027601
URL / URN: https://tuprints.ulb.tu-darmstadt.de/27601
Zugehörige Links:
Herkunft: Zweitveröffentlichung
Kurzbeschreibung (Abstract):

Spray cooling is a very efficient method for thermal management of high-performance electronics. The performance of spray cooling is determined by the fluid dynamics and the heat transport when a single drop or multiple drops hit the superheated wall. To understand this process, we numerically study the generic situation of simultaneous impingement of periodic drop arrays onto a superheated wall. We study three different cases in which the distance between the drops varies. The refrigerant used is perfluorohexane (FC-72) in a pure vapor atmosphere under saturation conditions. Drops impinge at moderate Reynolds and Weber numbers, where no splashing occurs during single drop impingement. The wall temperature is above the saturation temperature of the fluid but below the onset of nucleate boiling. Simulations are performed using the OpenFOAM software library, taking into account a dynamic contact angle, evaporation and conjugate heat transfer. We show that the coalescence of more than two drops results in the formation of a liquid jet. A small distance between the drops results in the formation of a thin liquid film while a large distance results in small drops sitting on the wall. In the latter case, the largest amount of heat is transferred, but the occurrence of dry spots is undesirable for cooling applications. The results contribute to a better understanding of spray cooling and provide a perspective for efficient spray cooling.

Status: Verlagsversion
URN: urn:nbn:de:tuda-tuprints-276016
Sachgruppe der Dewey Dezimalklassifikatin (DDC): 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften und Maschinenbau
Fachbereich(e)/-gebiet(e): 16 Fachbereich Maschinenbau
16 Fachbereich Maschinenbau > Fachgebiet für Technische Thermodynamik (TTD)
DFG-Sonderforschungsbereiche (inkl. Transregio)
DFG-Sonderforschungsbereiche (inkl. Transregio) > Sonderforschungsbereiche
DFG-Sonderforschungsbereiche (inkl. Transregio) > Sonderforschungsbereiche > SFB 1194: Wechselseitige Beeinflussung von Transport- und Benetzungsvorgängen
DFG-Sonderforschungsbereiche (inkl. Transregio) > Sonderforschungsbereiche > SFB 1194: Wechselseitige Beeinflussung von Transport- und Benetzungsvorgängen > Projektbereich C: Neue und verbesserte Anwendungen
DFG-Sonderforschungsbereiche (inkl. Transregio) > Sonderforschungsbereiche > SFB 1194: Wechselseitige Beeinflussung von Transport- und Benetzungsvorgängen > Projektbereich C: Neue und verbesserte Anwendungen > C02: Skalenübergreifende Experimente zum Sieden komplexer Fluide an komplexen Oberflächen
DFG-Sonderforschungsbereiche (inkl. Transregio) > Transregios
DFG-Sonderforschungsbereiche (inkl. Transregio) > Transregios > TRR 75 Tropfendynamische Prozesse unter extremen Umgebungsbedingungen
TU-Projekte: Bund/BMWi|03EN2026A|LoTuS
DFG|TRR75|TP C1 TRR 75
DFG|SFB1194|TP C02 Stephan
Hinterlegungsdatum: 05 Jul 2024 12:07
Letzte Änderung: 08 Jul 2024 05:33
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen