Kurzbeschreibung (Abstract)

With the experimental station STELLA (STELlar LAboratory) we will measure fusion cross sections of astrophysical relevance making use of the coincident detection of charged particles and gamma rays for background reduction. For the measurement of gamma rays from the de-excitation of fusion products a compact array of 36 UK FATIMA LaBr₃ detectors is designed based on efficiency studies with Geant4. The photo peak efficiency in the region of interest compares to other gamma detection systems used in this field.

The features of the internal decay of ¹³⁸La is used in a background study to obtain an online calibration of the gamma detectors. Background data are fit to the Monte Carlo model of the self activity assuming crude exponential behavior of external background. Accuracy in the region of interest is of the order of some keV in this first study.

Typ des Eintrags: Artikel
Erschienen: 2016
Autor(en): Heine, M. ; Courtin, S. ; Fruet, G. ; Jenkins, D.G. ; Montanari, D. ; Morris, L. ; Regan, P.H. ; Rudigier, M. ; Symochko, D.
Art des Eintrags: Bibliographie
Titel: Gamma Efficiency Simulations towards Coincidence Measurements for Fusion Cross Sections
Sprache: Englisch
Publikationsjahr: 2016
Ort: Bristol
Verlag: IOP Publishing
Titel der Zeitschrift, Zeitung oder Schriftenreihe: Journal of Physics: Conference Series
Jahrgang/Volume einer Zeitschrift: 763
(Heft-)Nummer: 1
Kollation: 6 Seiten
DOI: 10.1088/1742-6596/763/1/012005
Zugehörige Links:
Kurzbeschreibung (Abstract):

With the experimental station STELLA (STELlar LAboratory) we will measure fusion cross sections of astrophysical relevance making use of the coincident detection of charged particles and gamma rays for background reduction. For the measurement of gamma rays from the de-excitation of fusion products a compact array of 36 UK FATIMA LaBr₃ detectors is designed based on efficiency studies with Geant4. The photo peak efficiency in the region of interest compares to other gamma detection systems used in this field.

The features of the internal decay of ¹³⁸La is used in a background study to obtain an online calibration of the gamma detectors. Background data are fit to the Monte Carlo model of the self activity assuming crude exponential behavior of external background. Accuracy in the region of interest is of the order of some keV in this first study.

ID-Nummer: Artikel-ID: 012005
Zusätzliche Informationen:

Applications of Novel Scintillators for Research and Industry 2016 (ANSRI 2016) 11–13 May 2016, Dublin, Ireland

Sachgruppe der Dewey Dezimalklassifikatin (DDC): 500 Naturwissenschaften und Mathematik > 530 Physik
Fachbereich(e)/-gebiet(e): 05 Fachbereich Physik
05 Fachbereich Physik > Institut für Kernphysik
Hinterlegungsdatum: 13 Mai 2024 08:03
Letzte Änderung: 13 Mai 2024 08:03
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen