Koch, Myriam ; Bujotzek, Markus ; Franck, Christian M. (2014)
Inception level of partial discharges in SF6 induced with short X-ray pulses.
IEEE Conference on Electric Insulation and Dielectric Phenomena. Des Moines, USA (19.-22.10.2014)
doi: 10.1109/CEIDP.2014.6995781
Konferenzveröffentlichung, Bibliographie
Kurzbeschreibung (Abstract)
First generation gas insulated switchgears were constructed with large safety margin. Today's trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of the exact inception level of partial discharges due to those imperfections is of interest. The goal of the present contribution is to measure the discharge inception voltage in SF6 in a homogeneous field configuration with a small protrusion with unprecedented high accuracy. With a short pulse X-ray source first electrons are provided within the critical volume. The experimental results show for a 0.2 MPa SF6 insulation a threshold voltage of roughly 80 kV for positive and negative polarity at the protrusion, respectively. These inception voltages match the calculated theoretical inception level. The proposed method allows determining the inception voltage in a more efficient way as the experiment time is reduced.
Typ des Eintrags: | Konferenzveröffentlichung |
---|---|
Erschienen: | 2014 |
Autor(en): | Koch, Myriam ; Bujotzek, Markus ; Franck, Christian M. |
Art des Eintrags: | Bibliographie |
Titel: | Inception level of partial discharges in SF6 induced with short X-ray pulses |
Sprache: | Englisch |
Publikationsjahr: | 29 Dezember 2014 |
Verlag: | IEEE |
Buchtitel: | 2014 IEEE Conference on Electric Insulation and Dielectric Phenomena (CEIDP'14) |
Veranstaltungstitel: | IEEE Conference on Electric Insulation and Dielectric Phenomena |
Veranstaltungsort: | Des Moines, USA |
Veranstaltungsdatum: | 19.-22.10.2014 |
DOI: | 10.1109/CEIDP.2014.6995781 |
Kurzbeschreibung (Abstract): | First generation gas insulated switchgears were constructed with large safety margin. Today's trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of the exact inception level of partial discharges due to those imperfections is of interest. The goal of the present contribution is to measure the discharge inception voltage in SF6 in a homogeneous field configuration with a small protrusion with unprecedented high accuracy. With a short pulse X-ray source first electrons are provided within the critical volume. The experimental results show for a 0.2 MPa SF6 insulation a threshold voltage of roughly 80 kV for positive and negative polarity at the protrusion, respectively. These inception voltages match the calculated theoretical inception level. The proposed method allows determining the inception voltage in a more efficient way as the experiment time is reduced. |
Fachbereich(e)/-gebiet(e): | 18 Fachbereich Elektrotechnik und Informationstechnik 18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme > Hochspannungstechnik 18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme |
Hinterlegungsdatum: | 03 Apr 2024 13:49 |
Letzte Änderung: | 01 Aug 2024 11:30 |
PPN: | 520268822 |
Export: | |
Suche nach Titel in: | TUfind oder in Google |
Frage zum Eintrag |
Optionen (nur für Redakteure)
Redaktionelle Details anzeigen |