Barday, R. ; Aulenbacher, K. ; Bangert, P. ; Enders, J. ; Göök, A. ; Jakubassa-Amundsen, D. H. ; Nillius, F. ; Surzhykov, A. ; Yerokhin, V. A. (2024)
Compton transmission polarimeter for a very precise polarization measurement within a wide range of electron currents.
In: Journal of Physics: Conference Series, 2011, 298 (1)
doi: 10.26083/tuprints-00020678
Artikel, Zweitveröffentlichung, Verlagsversion
Es ist eine neuere Version dieses Eintrags verfügbar. |
Kurzbeschreibung (Abstract)
For new experiments with polarized electron and positron beams the precise and quick measurement of the beam polarization is required. The relative electron polarization has been monitored on-line using a compact transmission Compton polarimeter for a wide range of average electron currents up to 100/μA and electron beam energy of 3.5 MeV. The asymmetry induced by the beam polarization can be monitored precisely with ΔA/A < 0.2 %. Even small relative variations of the beam polarization during a beam time may be detected using this polarimeter, such as an increase ∼ 1 % and subsequent decrease of the beam polarization.
Typ des Eintrags: | Artikel |
---|---|
Erschienen: | 2024 |
Autor(en): | Barday, R. ; Aulenbacher, K. ; Bangert, P. ; Enders, J. ; Göök, A. ; Jakubassa-Amundsen, D. H. ; Nillius, F. ; Surzhykov, A. ; Yerokhin, V. A. |
Art des Eintrags: | Zweitveröffentlichung |
Titel: | Compton transmission polarimeter for a very precise polarization measurement within a wide range of electron currents |
Sprache: | Englisch |
Publikationsjahr: | 30 Januar 2024 |
Ort: | Darmstadt |
Publikationsdatum der Erstveröffentlichung: | 1 Mai 2011 |
Ort der Erstveröffentlichung: | Bristol |
Verlag: | IOP Publishing |
Titel der Zeitschrift, Zeitung oder Schriftenreihe: | Journal of Physics: Conference Series |
Jahrgang/Volume einer Zeitschrift: | 298 |
(Heft-)Nummer: | 1 |
Kollation: | 7 Seiten |
DOI: | 10.26083/tuprints-00020678 |
URL / URN: | https://tuprints.ulb.tu-darmstadt.de/20678 |
Zugehörige Links: | |
Herkunft: | Zweitveröffentlichung DeepGreen |
Kurzbeschreibung (Abstract): | For new experiments with polarized electron and positron beams the precise and quick measurement of the beam polarization is required. The relative electron polarization has been monitored on-line using a compact transmission Compton polarimeter for a wide range of average electron currents up to 100/μA and electron beam energy of 3.5 MeV. The asymmetry induced by the beam polarization can be monitored precisely with ΔA/A < 0.2 %. Even small relative variations of the beam polarization during a beam time may be detected using this polarimeter, such as an increase ∼ 1 % and subsequent decrease of the beam polarization. |
ID-Nummer: | Artikel-ID: 012022 |
Status: | Verlagsversion |
URN: | urn:nbn:de:tuda-tuprints-206788 |
Zusätzliche Informationen: | Workshop on Sources of Polarized Leptons and High Brightness Electron Beams (PESP2010) 21–24, September 2010, Bonn, Germany |
Sachgruppe der Dewey Dezimalklassifikatin (DDC): | 500 Naturwissenschaften und Mathematik > 530 Physik |
Fachbereich(e)/-gebiet(e): | 05 Fachbereich Physik 05 Fachbereich Physik > Institut für Kernphysik |
Hinterlegungsdatum: | 30 Jan 2024 13:19 |