TU Darmstadt / ULB / TUbiblio

Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath

Hanf, Stefan ; Bögözi, Timea ; Keiner, Robert ; Frosch, Torsten ; Popp, Jürgen (2015)
Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath.
In: Analytical Chemistry, 87 (2)
doi: 10.1021/ac503450y
Artikel, Bibliographie

Kurzbeschreibung (Abstract)

Breath gas analysis is a novel powerful technique for noninvasive, early-stage diagnosis of metabolic disorders or diseases. Molecular hydrogen and methane are biomarkers for colonic fermentation, because of malabsorption of oligosaccharides (e.g., lactose or fructose) and for small intestinal bacterial overgrowth. Recently, the presence of these gases in exhaled breath was also correlated with obesity. Here, we report on the highly selective and sensitive detection of molecular hydrogen and methane within a complex gas mixture (consisting of H2, CH4, N2, O2, and CO2) by means of fiber-enhanced Raman spectroscopy (FERS). An elaborate FERS setup with a microstructured hollow core photonic crystal fiber (HCPCF) provided a highly improved analytical sensitivity. The simultaneous monitoring of H2 with all other gases was achieved by a combination of rotational (H2) and vibrational (other gases) Raman spectroscopy within the limited spectral transmission range of the HCPCF. The HCPCF was combined with an adjustable image-plane aperture pinhole, in order to separate the H2 rotational Raman bands from the silica background signal and improve the sensitivity down to a limit of detection (LOD) of 4.7 ppm (for only 26 fmol H2). The ability to monitor the levels of H2 and CH4 in a positive hydrogen breath test (HBT) was demonstrated. The FERS sensor possesses a high dynamic range (∼5 orders of magnitude) with a fast response time of few seconds and provides great potential for miniaturization. We foresee that this technique will pave the way for fast, noninvasive, and painless point-of-care diagnosis of metabolic diseases in exhaled human breath.

Typ des Eintrags: Artikel
Erschienen: 2015
Autor(en): Hanf, Stefan ; Bögözi, Timea ; Keiner, Robert ; Frosch, Torsten ; Popp, Jürgen
Art des Eintrags: Bibliographie
Titel: Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath
Sprache: Englisch
Publikationsjahr: 20 Januar 2015
Verlag: ACS Publications
Titel der Zeitschrift, Zeitung oder Schriftenreihe: Analytical Chemistry
Jahrgang/Volume einer Zeitschrift: 87
(Heft-)Nummer: 2
DOI: 10.1021/ac503450y
Kurzbeschreibung (Abstract):

Breath gas analysis is a novel powerful technique for noninvasive, early-stage diagnosis of metabolic disorders or diseases. Molecular hydrogen and methane are biomarkers for colonic fermentation, because of malabsorption of oligosaccharides (e.g., lactose or fructose) and for small intestinal bacterial overgrowth. Recently, the presence of these gases in exhaled breath was also correlated with obesity. Here, we report on the highly selective and sensitive detection of molecular hydrogen and methane within a complex gas mixture (consisting of H2, CH4, N2, O2, and CO2) by means of fiber-enhanced Raman spectroscopy (FERS). An elaborate FERS setup with a microstructured hollow core photonic crystal fiber (HCPCF) provided a highly improved analytical sensitivity. The simultaneous monitoring of H2 with all other gases was achieved by a combination of rotational (H2) and vibrational (other gases) Raman spectroscopy within the limited spectral transmission range of the HCPCF. The HCPCF was combined with an adjustable image-plane aperture pinhole, in order to separate the H2 rotational Raman bands from the silica background signal and improve the sensitivity down to a limit of detection (LOD) of 4.7 ppm (for only 26 fmol H2). The ability to monitor the levels of H2 and CH4 in a positive hydrogen breath test (HBT) was demonstrated. The FERS sensor possesses a high dynamic range (∼5 orders of magnitude) with a fast response time of few seconds and provides great potential for miniaturization. We foresee that this technique will pave the way for fast, noninvasive, and painless point-of-care diagnosis of metabolic diseases in exhaled human breath.

Freie Schlagworte: Biomedical Spectroscopy, Breath Analysis, Fiber Enhanced Raman Spectroscopy FERS, Hydrogen Breath Test, Methane Test, Malabsorption Disorders, Lactose Intolerance, Small-intestinal-bacterial-overgrowth SIBO, Gas Sensing, Multigas Sensing, Gas Analysis, hollow core photonic crystal fiber
Fachbereich(e)/-gebiet(e): 18 Fachbereich Elektrotechnik und Informationstechnik
18 Fachbereich Elektrotechnik und Informationstechnik > Biophotonik-Medizintechnik
Hinterlegungsdatum: 19 Jan 2024 10:12
Letzte Änderung: 26 Apr 2024 08:08
PPN: 517559560
Export:
Suche nach Titel in: TUfind oder in Google
Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen