This article studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g., when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this article also discusses the effect of mechanical vibrations on the CCC performance.

Typ des Eintrags: Artikel
Erschienen: 2022
Autor(en): Marsic, Nicolas ; Muller, Wolfgang F. O. ; Tympel, Volker ; Stohlker, Thomas ; Stapelfeld, Max ; Schmidl, Frank ; Schmelz, Matthias ; Zakosarenko, Vyacheslav ; Stolz, Ronny ; Haider, David ; Sieber, Thomas ; Schwickert, Marcus ; De Gersem, Herbert
Art des Eintrags: Bibliographie
Titel: Influence of Mechanical Deformations on the Performance of a Coaxial Shield for a Cryogenic Current Comparator
Sprache: Englisch
Publikationsjahr: Dezember 2022
Verlag: IEEE
Titel der Zeitschrift, Zeitung oder Schriftenreihe: IEEE Transactions on Applied Superconductivity
Jahrgang/Volume einer Zeitschrift: 32
(Heft-)Nummer: 9
DOI: 10.1109/TASC.2022.3206607
Kurzbeschreibung (Abstract):

This article studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g., when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this article also discusses the effect of mechanical vibrations on the CCC performance.

Fachbereich(e)/-gebiet(e): 18 Fachbereich Elektrotechnik und Informationstechnik
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Teilchenbeschleunigung und Theorie Elektromagnetische Felder
Hinterlegungsdatum: 12 Okt 2022 08:02
Letzte Änderung: 11 Aug 2023 08:12
PPN: 510579957
Export:
Suche nach Titel in: TUfind oder in Google
Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen