TU Darmstadt / ULB / TUbiblio

Estimating Xtop lattice artifacts from flowed SU(2) calorons

Jahn, Peter Thomas ; Moore, Guy D. ; Robaina, Daniel (2022)
Estimating Xtop lattice artifacts from flowed SU(2) calorons.
In: The European Physical Journal C, 2019, 79 (6)
doi: 10.26083/tuprints-00012773
Artikel, Zweitveröffentlichung, Verlagsversion

WarnungEs ist eine neuere Version dieses Eintrags verfügbar.

Kurzbeschreibung (Abstract)

Lattice computations of the high-temperature topological susceptibility of QCD receive lattice-spacing corrections and suffer from systematics arising from the type and depth of gradient flow. We study the lattice spacing corrections to Xtop semi-analytically by exploring the behavior of discretized Harrington–Shepard calorons under the action of different forms of gradient flow. From our study we conclude that Nτ = 6 is definitely too small of a time extent to study the theory at temperatures of order 4 Tc and we explore how the amount of gradient flow influences the continuum extrapolation.

Typ des Eintrags: Artikel
Erschienen: 2022
Autor(en): Jahn, Peter Thomas ; Moore, Guy D. ; Robaina, Daniel
Art des Eintrags: Zweitveröffentlichung
Titel: Estimating Xtop lattice artifacts from flowed SU(2) calorons
Sprache: Englisch
Publikationsjahr: 2022
Publikationsdatum der Erstveröffentlichung: 2019
Verlag: Springer
Titel der Zeitschrift, Zeitung oder Schriftenreihe: The European Physical Journal C
Jahrgang/Volume einer Zeitschrift: 79
(Heft-)Nummer: 6
Kollation: 11 Seiten
DOI: 10.26083/tuprints-00012773
URL / URN: https://tuprints.ulb.tu-darmstadt.de/12773
Zugehörige Links:
Herkunft: Zweitveröffentlichung
Kurzbeschreibung (Abstract):

Lattice computations of the high-temperature topological susceptibility of QCD receive lattice-spacing corrections and suffer from systematics arising from the type and depth of gradient flow. We study the lattice spacing corrections to Xtop semi-analytically by exploring the behavior of discretized Harrington–Shepard calorons under the action of different forms of gradient flow. From our study we conclude that Nτ = 6 is definitely too small of a time extent to study the theory at temperatures of order 4 Tc and we explore how the amount of gradient flow influences the continuum extrapolation.

Status: Verlagsversion
URN: urn:nbn:de:tuda-tuprints-127730
Sachgruppe der Dewey Dezimalklassifikatin (DDC): 500 Naturwissenschaften und Mathematik > 530 Physik
Fachbereich(e)/-gebiet(e): 05 Fachbereich Physik
05 Fachbereich Physik > Institut für Kernphysik
05 Fachbereich Physik > Institut für Kernphysik > Theoretische Kernphysik
Hinterlegungsdatum: 02 Mär 2022 09:28
Letzte Änderung: 03 Mär 2022 09:32
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen