Jahn, Peter Thomas ; Moore, Guy D. ; Robaina, Daniel (2022)
Estimating Xtop lattice artifacts from flowed SU(2) calorons.
In: The European Physical Journal C, 2019, 79 (6)
doi: 10.26083/tuprints-00012773
Artikel, Zweitveröffentlichung, Verlagsversion
Es ist eine neuere Version dieses Eintrags verfügbar. |
Kurzbeschreibung (Abstract)
Lattice computations of the high-temperature topological susceptibility of QCD receive lattice-spacing corrections and suffer from systematics arising from the type and depth of gradient flow. We study the lattice spacing corrections to Xtop semi-analytically by exploring the behavior of discretized Harrington–Shepard calorons under the action of different forms of gradient flow. From our study we conclude that Nτ = 6 is definitely too small of a time extent to study the theory at temperatures of order 4 Tc and we explore how the amount of gradient flow influences the continuum extrapolation.
Typ des Eintrags: | Artikel |
---|---|
Erschienen: | 2022 |
Autor(en): | Jahn, Peter Thomas ; Moore, Guy D. ; Robaina, Daniel |
Art des Eintrags: | Zweitveröffentlichung |
Titel: | Estimating Xtop lattice artifacts from flowed SU(2) calorons |
Sprache: | Englisch |
Publikationsjahr: | 2022 |
Publikationsdatum der Erstveröffentlichung: | 2019 |
Verlag: | Springer |
Titel der Zeitschrift, Zeitung oder Schriftenreihe: | The European Physical Journal C |
Jahrgang/Volume einer Zeitschrift: | 79 |
(Heft-)Nummer: | 6 |
Kollation: | 11 Seiten |
DOI: | 10.26083/tuprints-00012773 |
URL / URN: | https://tuprints.ulb.tu-darmstadt.de/12773 |
Zugehörige Links: | |
Herkunft: | Zweitveröffentlichung |
Kurzbeschreibung (Abstract): | Lattice computations of the high-temperature topological susceptibility of QCD receive lattice-spacing corrections and suffer from systematics arising from the type and depth of gradient flow. We study the lattice spacing corrections to Xtop semi-analytically by exploring the behavior of discretized Harrington–Shepard calorons under the action of different forms of gradient flow. From our study we conclude that Nτ = 6 is definitely too small of a time extent to study the theory at temperatures of order 4 Tc and we explore how the amount of gradient flow influences the continuum extrapolation. |
Status: | Verlagsversion |
URN: | urn:nbn:de:tuda-tuprints-127730 |
Sachgruppe der Dewey Dezimalklassifikatin (DDC): | 500 Naturwissenschaften und Mathematik > 530 Physik |
Fachbereich(e)/-gebiet(e): | 05 Fachbereich Physik 05 Fachbereich Physik > Institut für Kernphysik 05 Fachbereich Physik > Institut für Kernphysik > Theoretische Kernphysik |
Hinterlegungsdatum: | 02 Mär 2022 09:28 |
Letzte Änderung: | 03 Mär 2022 09:32 |
PPN: | |
Export: | |
Suche nach Titel in: | TUfind oder in Google |
Verfügbare Versionen dieses Eintrags
- Estimating Xtop lattice artifacts from flowed SU(2) calorons. (deposited 02 Mär 2022 09:28) [Gegenwärtig angezeigt]
Frage zum Eintrag |
Optionen (nur für Redakteure)
Redaktionelle Details anzeigen |