TU Darmstadt / ULB / TUbiblio

Assessment of the impact of multiple mild-steam decontaminations on the protection performance of disposable KN95 filtering facepiece respirators

Zentgraf, Florian ; Johe, Pascal ; Hoche, Holger ; Göckel, Bernd ; Becker, S. ; Oechsner, Matthias ; Dreizler, Andreas (2021)
Assessment of the impact of multiple mild-steam decontaminations on the protection performance of disposable KN95 filtering facepiece respirators.
In: Infection Prevention in Practice, 2021, 3 (2)
doi: 10.26083/tuprints-00019343
Artikel, Zweitveröffentlichung, Verlagsversion

WarnungEs ist eine neuere Version dieses Eintrags verfügbar.

Kurzbeschreibung (Abstract)

The COVID-19 pandemic caused tremendous supply bottlenecks of single-use filtering facepiece respirators (FFRs) leading to a growing need for a potential reuse. This study assesses the impact of multiple mild-steam decontaminations with 121 °C/2000 mbar/20 min on the protection performance of disposable FFRs. It focuses on FFRs of type KN95 that is recently dominating the markets, but its decontamination is not covered in the literature. It was found that up to ten cycles, only minor degradation in the filter efficiency, breathing resistance and none in the material structure is apparent, suggesting a potential for multiple decontamination cycles at almost unchanged protective properties of KN95 FFRs.

Typ des Eintrags: Artikel
Erschienen: 2021
Autor(en): Zentgraf, Florian ; Johe, Pascal ; Hoche, Holger ; Göckel, Bernd ; Becker, S. ; Oechsner, Matthias ; Dreizler, Andreas
Art des Eintrags: Zweitveröffentlichung
Titel: Assessment of the impact of multiple mild-steam decontaminations on the protection performance of disposable KN95 filtering facepiece respirators
Sprache: Englisch
Publikationsjahr: 2021
Publikationsdatum der Erstveröffentlichung: 2021
Verlag: Elsevier
Titel der Zeitschrift, Zeitung oder Schriftenreihe: Infection Prevention in Practice
Jahrgang/Volume einer Zeitschrift: 3
(Heft-)Nummer: 2
Kollation: 6 Seiten
DOI: 10.26083/tuprints-00019343
URL / URN: https://tuprints.ulb.tu-darmstadt.de/19343
Zugehörige Links:
Herkunft: Zweitveröffentlichung aus gefördertem Golden Open Access
Kurzbeschreibung (Abstract):

The COVID-19 pandemic caused tremendous supply bottlenecks of single-use filtering facepiece respirators (FFRs) leading to a growing need for a potential reuse. This study assesses the impact of multiple mild-steam decontaminations with 121 °C/2000 mbar/20 min on the protection performance of disposable FFRs. It focuses on FFRs of type KN95 that is recently dominating the markets, but its decontamination is not covered in the literature. It was found that up to ten cycles, only minor degradation in the filter efficiency, breathing resistance and none in the material structure is apparent, suggesting a potential for multiple decontamination cycles at almost unchanged protective properties of KN95 FFRs.

Status: Verlagsversion
URN: urn:nbn:de:tuda-tuprints-193436
Zusätzliche Informationen:

Keywords: Sterilization Face mask Respirator Filtration efficiency KN95 COVID-19

Sachgruppe der Dewey Dezimalklassifikatin (DDC): 600 Technik, Medizin, angewandte Wissenschaften > 600 Technik
600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin, Gesundheit
Fachbereich(e)/-gebiet(e): 16 Fachbereich Maschinenbau
16 Fachbereich Maschinenbau > Fachgebiet und Institut für Werkstoffkunde - Zentrum für Konstruktionswerkstoffe - Staatliche Materialprüfungsanstalt Darmstadt (IfW-MPA)
16 Fachbereich Maschinenbau > Fachgebiet Reaktive Strömungen und Messtechnik (RSM)
Hinterlegungsdatum: 23 Aug 2021 12:06
Letzte Änderung: 31 Aug 2021 05:21
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen