TU Darmstadt / ULB / TUbiblio

Development and Optimization of a Pulsed Electroacoustic System with Temperature Controlled Electrodes

Hussain, Rashid ; Hinrichsen, Volker (2019)
Development and Optimization of a Pulsed Electroacoustic System with Temperature Controlled Electrodes.
26th Nordic Insulation Symposium on Materials, Components and Diagnostics. Tampere, Finnland (12.06.2019-14.06.2019)
doi: 10.5324/nordis.v0i26.3278
Konferenzveröffentlichung, Bibliographie

Dies ist die neueste Version dieses Eintrags.

Kurzbeschreibung (Abstract)

This work presents the important steps in developing and optimizing a Pulsed Electroacoustic (PEA) system. The aim is to investigate silicone rubbers (LSR) with different amount of nanofillers. Therefore, the influence of the nanofillers on the acoustic behavior such as the acoustic impedance and the speed of sound is investigated. A detailed description of the acoustic detection unit is provided. To allow the measurement at different absolute temperatures and also at temperature gradients the electrodes are temperature controlled. Reference measurements are performed to give a better and more accurate temperature profile estimation inside the samples. The influence of temperature on the attenuation and dispersion factors of different LSR samples is outlined. A final procedure for signal processing is presented to determine the correct space charge distribution.

Typ des Eintrags: Konferenzveröffentlichung
Erschienen: 2019
Autor(en): Hussain, Rashid ; Hinrichsen, Volker
Art des Eintrags: Bibliographie
Titel: Development and Optimization of a Pulsed Electroacoustic System with Temperature Controlled Electrodes
Sprache: Englisch
Publikationsjahr: 12 Juni 2019
Veranstaltungstitel: 26th Nordic Insulation Symposium on Materials, Components and Diagnostics
Veranstaltungsort: Tampere, Finnland
Veranstaltungsdatum: 12.06.2019-14.06.2019
DOI: 10.5324/nordis.v0i26.3278
URL / URN: https://www.ntnu.no/ojs/index.php/nordis/index
Kurzbeschreibung (Abstract):

This work presents the important steps in developing and optimizing a Pulsed Electroacoustic (PEA) system. The aim is to investigate silicone rubbers (LSR) with different amount of nanofillers. Therefore, the influence of the nanofillers on the acoustic behavior such as the acoustic impedance and the speed of sound is investigated. A detailed description of the acoustic detection unit is provided. To allow the measurement at different absolute temperatures and also at temperature gradients the electrodes are temperature controlled. Reference measurements are performed to give a better and more accurate temperature profile estimation inside the samples. The influence of temperature on the attenuation and dispersion factors of different LSR samples is outlined. A final procedure for signal processing is presented to determine the correct space charge distribution.

Fachbereich(e)/-gebiet(e): 18 Fachbereich Elektrotechnik und Informationstechnik
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme > Hochspannungstechnik
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme
Hinterlegungsdatum: 02 Dez 2019 12:34
Letzte Änderung: 04 Dez 2019 09:31
PPN:
Export:
Suche nach Titel in: TUfind oder in Google

Verfügbare Versionen dieses Eintrags

  • Development and Optimization of a Pulsed Electroacoustic System with Temperature Controlled Electrodes. (deposited 02 Dez 2019 12:34) [Gegenwärtig angezeigt]
Frage zum Eintrag Frage zum Eintrag

Optionen (nur für Redakteure)
Redaktionelle Details anzeigen Redaktionelle Details anzeigen