Abstract

A multitude of 'arc tracking' tests on cables for space applications has been performed to improve the basic understanding of the phenomena responsible for the fault arc behavior. The damage in a cable bundle develops in a complex system consisting of metallic conductors, insulation materials and arc plasma. Considering the degradation effects, vacuum as one of the applied test parameters, has turned out to be an important test environment. The investigations are based on a new test method, developed to assess arc tracking properties of cables for space applications. Tests were conducted with different insulation materials at cables with different AWG at 125 V dc and nominal currents. The tests were focused on the vacuum environment, using air only for the purpose of comparison. For some cable types, vacuum has turned out to be a worst-case environmental condition with respect to fault arc effects, such as the conductor burn-off, degradation of the insulation of adjacent cables and the extension of the fault arc. This paper presents these worst case experiments in detail.

Item Type: Article
Erschienen: 1997
Creators: Hanson, Josef ; Koenig, Dieter
Type of entry: Bibliographie
Title: Fault arcs effects in cable bundles for space applications in vacuum
Language: English
Date: 1 August 1997
Publisher: IEEE
Journal or Publication Title: IEEE Transactions on Dielectrics and Electrical Insulation
Volume of the journal: 4
Issue Number: 4
DOI: 10.1109/94.625354
Abstract:

A multitude of 'arc tracking' tests on cables for space applications has been performed to improve the basic understanding of the phenomena responsible for the fault arc behavior. The damage in a cable bundle develops in a complex system consisting of metallic conductors, insulation materials and arc plasma. Considering the degradation effects, vacuum as one of the applied test parameters, has turned out to be an important test environment. The investigations are based on a new test method, developed to assess arc tracking properties of cables for space applications. Tests were conducted with different insulation materials at cables with different AWG at 125 V dc and nominal currents. The tests were focused on the vacuum environment, using air only for the purpose of comparison. For some cable types, vacuum has turned out to be a worst-case environmental condition with respect to fault arc effects, such as the conductor burn-off, degradation of the insulation of adjacent cables and the extension of the fault arc. This paper presents these worst case experiments in detail.

Divisions: 18 Department of Electrical Engineering and Information Technology
18 Department of Electrical Engineering and Information Technology > Institute for Electrical Power Systems > High Voltage Technology
18 Department of Electrical Engineering and Information Technology > Institute for Electrical Power Systems
Date Deposited: 19 Nov 2008 16:05
Last Modified: 10 May 2023 10:19
PPN:
Export:
Suche nach Titel in: TUfind oder in Google
Send an inquiry Send an inquiry

Options (only for editors)
Show editorial Details Show editorial Details